.. _Environmental Specifications: Environmental Specifications ---------------------------- Appliance environmental specifications are listed in the following tables. .. tabularcolumns:: |>{\TL}\X{2}{3}% |>{\TL}\X{1}{3}| .. table:: :class: longtable +--------------------------------------------------+----------------------------------+ | Store temperature | -40 |deg| C to 85 |deg| C | | | (-40 |deg| F to 185 |deg| F) | +--------------------------------------------------+----------------------------------+ | Store temperature gradient | 20 |deg| C (68 |deg| F) per hour | +--------------------------------------------------+----------------------------------+ | Operating temperature | 10 |deg| C to 35 |deg| C | | | (50 |deg| F to -95 |deg| F) | +--------------------------------------------------+----------------------------------+ | Operating temperature gradient | 20 |deg| C (68 |deg| F) per hour | +--------------------------------------------------+----------------------------------+ | Relative humidity percentage range for storage | 10% ~ 95% (non-condensing) | +--------------------------------------------------+----------------------------------+ | Relative humidity percentage range for operating | 10% ~ 85% (non-condensing) | +--------------------------------------------------+----------------------------------+ | Vibration for storage | 1.87 Grms (10-500 Hz) | +--------------------------------------------------+----------------------------------+ | Vibration for operating | 0.26 Grms (5-350 Hz) | +--------------------------------------------------+----------------------------------+ | Shock for storage | 65G for 2ms | +--------------------------------------------------+----------------------------------+ | Shock for operating | 5G | +--------------------------------------------------+----------------------------------+ | Altitude for storage | 12,000m (39,370 ft) | +--------------------------------------------------+----------------------------------+ | Altitude for operating | 3,048m (10,000 ft) | +--------------------------------------------------+----------------------------------+ Air Quality Requirements ~~~~~~~~~~~~~~~~~~~~~~~~ The air must be free of: - corrosive dust and/or corrosive contaminants - conductive dust or conductive particles (such as zinc whiskers) Airborne residual dust must have a deliquescent point\* less than 60% relative humidity. (\*The relative humidity at which crystalline materials begin adsorbing large quantities of water from the atmosphere.) Gaseous corrosion level in terms of (in Angstrom) as per ISA: - Copper reactivity rate must be less than 300 |ang| /month, class G1(ANSI/ISA71.04-1985). - Silver reactivity rate must be less than 200 |ang| /month (AHSRAE TC9.9).